Tuesday, November 16, 2010

Reuben's Quick Tip: Caulk Doesn't Belong Here, Part II

Last week I blogged about not caulking at the base of storm windows, which is a simple no-brainer. Another place that should never be caulked is the space between the siding and the flashing above a window; this piece of flashing is often referred to as drip flashing, drip cap, or head flashing.  Caulking this opening shut is a very common defect, even on new construction.
Caulked head flashing
Why not caulk here? The head flashing at the window provides a drainage plane for water that could potentially get in behind the siding; the head flashing allows the water to drain out above the top of the window.  If the space between the flashing and the siding gets caulked shut, where will water go?  It will get trapped behind the siding and potentially cause damage to the home.
Some siding manufacturers already require this space to be left open, such as fiber-cement siding manufacturers.  Unfortunately, this detail isn’t spelled out in any window installation instruction manuals, or if it is, I haven’t found them yet.   I also haven’t found any vinyl siding manufacturers that specifically say “don’t caulk here“.  For fiber-cement siding, it’s an installation defect.  For just about any other type of siding, including vinyl, it’s a ‘best practice’ not to caulk here.
Don't caulk head flashing
Just wait though… I’m sure that the manufacturers of windows and other types of siding will catch up on this detail soon enough, and they’ll start explicitly telling you “don’t caulk here”.  Installation instructions for windows are getting longer and more specific every year.  Case in point: about ten years ago, Windsor Windows published a one page installation sheet; today it’s aten page installation manual.  Did the windows change significantly?  No.  Manufacturers are just doing their part to help prevent failures from improper installations.
Is this really a defectWell, technically no, not on all installations.  It’s not a defect until the manufacturers put it in writing or it’s specified in the building code… but it sure isn’t wise.
Reuben Saltzman, Structure Tech Home Inspections - EmailMinneapolis Home Inspections
Facebook Reuben's LinkedIn Page Follow StructureTech on Twitter ASHI Certified Home Inspector - Click To Verify Click to subscibe to Reuben's Blog

Tuesday, November 9, 2010

Reuben's Quick Tip: Caulk Doesn't Belong Here

If I'm going to write a blog about caulk, I need to get something out of the way first; it's pronounced kawk, not kallllk.  The "L" is silent, and the word rhymes with walk or talk.  If you're uncomfortable uttering this word aloud, try 'sealant' instead.  Moving on.

As we learned from Charles Buelle's blog about caulking not caulking at the base of tiled shower walls, there are just some places where caulking doesn't belong.

One of the most common offenders is at the bottom of storm windows; if the base of the storm window gets caulked shut, where does the water go?

Caulk at base of storm window

Nowhere.  It just sits there and rots the window out.  Most storm windows already come with weep holes in the bottom of the window to allow water to drain out; keep these holes open.

Weep holes

When I find caulking at the base of storm windows, I recommend repair.  The fix can be as simple as drilling a bunch of holes at the base of the storm window.